inomed healthcare MedTech

Fetal medicine · Prenatal diagnosis

Chorionic villus sampling and amniocentesis needles.

CVS and amniocentesis biopsy needles for UK fetal medicine units — echogenic under ultrasound, colour-coded by gauge, sterile and single use. Supplied throughout the United Kingdom by Inomed Health Limited, a distributor of single-use medical devices to NHS hospitals.

ChorionSet  20 G & 22 G coaxial sets Amnio  18–22 G, 90–220 mm 10  per box

What a trust is buying from

  • UK Responsible PersonFor the manufacturer, under the UK MDR
  • Supplying NHS hospitals since 2004Sterile single-use devices, direct
  • Sterile & single useIndividually pouched, ten to a box
  • Full documentationBatch traceability with every order

Chorionic villus sampling

ChorionSet — transabdominal CVS set

Chorionic villus sampling detects the presence or absence of genetic disorders at an earlier stage than amniocentesis. Sampling is performed transabdominally under ultrasound guidance.

The three components of the ChorionSet, shown top to bottom: the coaxial introducer with its winged grip, the stylet, and the graduated villus sampling needle.
Set components — coaxial introducer, stylet and villus sampling needle, shown top to bottom. The sampling needle carries an echogenic marker so the tip stays visible on the scan; both cannulae carry centimetre markings and the stylet hub is colour-coded by gauge.
PBUTxxyy

The set contains two devices: a coaxial introducer needle and a villus sampling needle. The introducer allows the sampling needle to reach the biopsy site through the abdominal wall, so a second pass can be taken without a second puncture.

  • Chiba tip cannulaSharpened tip on the villus sampling needle
  • Echogenic markerClear visualisation under ultrasound
  • Wings for secure gripOn the coaxial introducer
  • Colour-coded styletIdentifies gauge at a glance

Ordering information

CodeVillus needleCoaxialVillus lengthCoaxial lengthQty
PBUT201520 G18 G150 mm90 mmBox of 10
PBUT2020 Most ordered20 G18 G200 mm140 mmBox of 10
PBUT2022 Widest bore, longest reach20 G18 G220 mm160 mmBox of 10
PBUT222222 G19 G220 mm160 mmBox of 10
Single-needle technique — ordered separately, not as a set
PBU181518 G—150 mm—Box of 10
PBU182018 G—200 mm—Box of 10
PBU202020 G—200 mm—Box of 10

PBUTxxyy — xx is the gauge of the villus sampling needle, yy its length. PBUT2022 is a 20 G, 220 mm villus sampling needle.

Single-needle technique

Where a coaxial approach is not preferred, or a unit does not wish to purchase a complete set, the sampling needle is supplied on its own.

PBU1815 — 18 G, 150 mm. PBU1820 — 18 G, 200 mm. PBU2020 — 20 G, 200 mm.

The same chiba needle listed under Amnio below. ISUOG gives 17–20 G for a single-needle transabdominal approach, so both gauges are held and a unit orders to its own protocol; PBU1815 also serves as the coaxial guide needle where coaxial access is wanted. Ordered as separate references rather than as a set, so a unit takes only what it uses. Sterile, single use, ten per box. The choice of gauge and technique rests with the operator.

ChorionSet brochurePDF, 3 pages · IH-CYTO-BIOPSY-001 · 0.3 MB
Packaging Pouch Per box 10 sets Included Villus sampling needle, coaxial needle, sliding stopper, cannula protection

Amniocentesis

Amnio — chiba needle with ultra point

A disposable needle for transabdominal sampling of amniotic fluid for prenatal diagnosis of genetic disorders of the fetus.

The Amnio needle: a graduated stainless steel cannula with a sharpened, echogenic chiba tip, a sliding stopper on the shaft and a colour-coded luer lock hub.
Amnio needle — graduated cannula with a sharpened, echogenic chiba tip, sliding stopper for depth, and a colour-coded luer lock hub for syringe connection.
PBUxxyy

A stainless steel cannula with a sharpened chiba tip reaches deep-seated sampling sites. The hub carries a luer lock connection to collect amniotic fluid through a syringe.

  • Echogenic markerCorrect placement under ultrasound guidance
  • Centimetre markingsInsertion depth read directly off the cannula
  • Sliding stopperDepth set before the pass
  • Colour-coded hubGauge identified without reading the label

Ordering information

CodeGaugeLengthQtyCodeGaugeLengthQty
PBU181518 G150 mmBox of 10PBU211521 G150 mmBox of 10
PBU182018 G200 mmBox of 10PBU212021 G200 mmBox of 10
PBU200920 G90 mmBox of 10PBU212221 G220 mmBox of 10
PBU201220 G120 mmBox of 10PBU220922 G90 mmBox of 10
PBU2015 Most ordered20 G150 mmBox of 10PBU221222 G120 mmBox of 10
PBU202020 G200 mmBox of 10PBU221522 G150 mmBox of 10
PBU202220 G220 mmBox of 10PBU222022 G200 mmBox of 10
PBU210921 G90 mmBox of 10PBU222222 G220 mmBox of 10
PBU211221 G120 mmBox of 10

PBUxxyy — xx is the gauge, yy the length. Seventeen references from 18 G to 22 G, 90 mm to 220 mm.

Amnio brochurePDF, 3 pages · IH-CYTO-AMNIO-001 · 0.5 MB
Packaging Pouch Per box 10 needles Included Amnio needle, sliding stopper, cannula protection

Transabdominal coaxial technique

How the CVS set is used

A schematic overview of the published technique for transabdominal chorionic villus sampling with a coaxial set. It is not a substitute for the Instructions for Use.

Assess and select the site

Confirm viability, gestational age, liquor volume and placental location. Choose a track clear of the fetus.

Prepare an aseptic field

Clean the skin with antiseptic, apply a sterile drape and use separate sterile gel. Local anaesthetic optional.

Place the coaxial introducer

Under ultrasound guidance, advance the introducer and stylet to the placental edge. The wings give a secure grip.

Withdraw the stylet

Hold the introducer in position and remove the stylet. The colour-coded hub identifies the gauge.

Sample the villi

Pass the echogenic sampling needle through the introducer. Attach a syringe, apply suction and make back-and-forth passes.

Inspect, repeat or withdraw

Check the aspirate for villi. A further pass may be taken through the introducer, then withdraw and check the fetal heart.

CVS is performed after 10+0 weeks, commonly between 11+0 and 13+6. Around 5 mg of chorionic villi is the minimum for a single molecular test; laboratories commonly request 20–30 mg, and more where both molecular analysis and culture are planned — confirm the required sample weight with the receiving cytogenetics laboratory. Confirm fetal cardiac activity afterwards, and offer anti-D immunoglobulin within 72 hours to non-sensitised RhD-negative women unless the fetus is known to be RhD-negative. Schematic overview only — the procedure must be performed by an appropriately trained operator under continuous ultrasound guidance, following the Instructions for Use supplied with the product and local clinical protocol. Technique summarised from ISUOG Practice Guidelines: invasive procedures for prenatal diagnosis (2016) and RCOG Green-top Guideline No. 8 (2021).

Transabdominal amniocentesis

How the Amnio needle is used

A schematic overview of the published technique for transabdominal amniocentesis. It is not a substitute for the Instructions for Use.

Assess and select the site

Confirm viability, gestational age, liquor volume and placental location. Choose a pocket of liquor clear of the fetus.

Prepare an aseptic field

Clean the skin with antiseptic, apply a sterile drape and use separate sterile gel. Local anaesthetic optional.

Insert the needle

A 20–22 G needle is advanced transabdominally under continuous ultrasound guidance. Set the sliding stopper to the intended depth first. Avoid the placenta where technically feasible.

Withdraw the stylet

Hold the cannula in position and remove the stylet. The colour-coded hub identifies the gauge.

Aspirate the sample

Attach a syringe to the luer lock hub. Discard the first 2 mL to minimise maternal cell contamination, then aspirate 15–30 mL depending on the indication.

Withdraw and check

Replace the stylet, withdraw the needle and confirm fetal cardiac activity.

Amniocentesis is performed at or beyond 15+0 weeks; earlier procedures carry higher rates of pregnancy loss, talipes equinovarus and fluid leakage. The first 2 mL is discarded to minimise maternal cell contamination, and between 15 and 30 mL is then aspirated, depending on the indication and the receiving laboratory’s requirements. Confirm fetal cardiac activity afterwards, and offer anti-D immunoglobulin within 72 hours to non-sensitised RhD-negative women unless the fetus is known to be RhD-negative. Schematic overview only — the procedure must be performed by an appropriately trained operator under continuous ultrasound guidance, following the Instructions for Use supplied with the product and local clinical protocol. Technique summarised from ISUOG Practice Guidelines: invasive procedures for prenatal diagnosis (2016) and RCOG Green-top Guideline No. 8 (2021).

Supply

Ordering from Inomed

A named contact, not a portal

Quotations, product queries and order tracking are answered by the order desk by a person who knows the range.

Evaluation samples

Units trialling a gauge or length before committing to a change of supplier can request evaluation stock against a named consultant.

Full documentation

Instructions for Use, declarations and batch traceability are supplied with every order and held against the consignment.

Common questions

CVS and amniocentesis needles — questions we are asked

Answers to what fetal medicine units and procurement teams ask before ordering. For anything not covered here, the order desk will answer it directly.

What gauge needle is used for chorionic villus sampling?

Transabdominal CVS is most often performed with a coaxial set. The ChorionSet is supplied in 20 G and 22 G, the introducer and the villus sampling needle matched as a pair, with the stylet hub colour-coded by gauge so the correct size is identifiable on the trolley without reading the label.

What is the difference between a CVS needle and an amniocentesis needle?

A CVS set is coaxial: an introducer cannula is placed first, the stylet withdrawn, and the sampling needle passed down it, so the placenta is entered once however many passes are taken. An amniocentesis needle is a single chiba needle passed directly into the amniotic cavity. They are different instruments for different procedures and are not interchangeable.

Can CVS be performed without a coaxial introducer?

Yes. Some operators prefer a single-needle approach, and some units do not wish to purchase a complete set. For those the sampling needle is supplied on its own: PBU1815, an 18 G, 150 mm needle; PBU1820, an 18 G, 200 mm needle; and PBU2020, a 20 G, 200 mm needle. It is the same chiba needle listed under the Amnio range, and ISUOG gives 17 to 20 G for a single-needle transabdominal approach. PBU1815 also serves as the coaxial guide needle where coaxial access is wanted. All are sterile, single use and supplied ten per box. The choice of gauge and technique rests with the operator.

Are the needles echogenic?

Yes. Both the ChorionSet and the Amnio needle are echogenic, so the tip is visible under continuous ultrasound guidance throughout the procedure.

What sizes are the amniocentesis needles available in?

The Amnio chiba needle is supplied from 18 G to 22 G in lengths from 90 mm to 220 mm, graduated along the shaft, with a sliding stopper for depth and a colour-coded luer lock hub for syringe connection.

How are they supplied?

Sterile and single use, ten to a box. A ChorionSet box holds ten complete coaxial sets, each pouch containing the villus sampling needle and its introducer; an Amnio box holds ten needles. Full product documentation is provided, and the Instructions for Use supplied with the product govern the technique.

Who supplies CVS and amniocentesis needles in the UK?

Inomed Health Limited supplies both the ChorionSet CVS sets and the Amnio amniocentesis needles throughout the United Kingdom. Orders and quotations are handled by a named contact on the order desk rather than through a portal.

Can we have an evaluation sample before ordering?

Yes. Evaluation samples are available to fetal medicine units considering a change of supplier. Request one with the enquiry form below, or by telephone.

Contact

Request a quotation or an evaluation sample

Tell us which product and we will come back with pricing, lead time and availability. Evaluation samples are available to units considering a change of supplier.

Sizes required tick every size you need

ChorionSet — coaxial CVS set

Amnio — amniocentesis needle

18 G

20 G

21 G

22 G

Not listed? Just type it in — the list is a shortcut, not a restriction.

Tick either or both. The download starts as soon as you send, and the order desk is told which you asked for so they come with the reply as well.

Sent straight to our order desk. We use what you enter here only to answer your enquiry — nothing else, and we pass it to nobody.

Orders and quotations
Customer service
Product and clinical support
Inomed Health Limited
The Elsie Whiteley Innovation Centre
Hopwood Lane
Halifax, West Yorkshire
HX1 5ER, United Kingdom